Hampton 24孔坐滴板 Cryschem Plate

Hampton 24孔坐滴板 Cryschem Plate
Applications
 Sitting drop crystallization
  Heavy atom soaks
  Seeding

Features
Optically clear, concave sitting drop post
Cryschem Plate – Larger footprint and round reagent reservoir
Cryschem M – Microplate footprint with round reagent reservoir
Cryschem S – Microplate footprint with square reagent reservoir
Compatible with Formulatrix Formulator
Smooth, flat top for easy seal
Each plate supplied with a cover
Materials
  Optically clear polystyrene
 Description

The Cryschem Plate is a 24 well sitting drop plate that is sealed with clear sealing tape. The polystyrene plate is supplied with a raised cover so the plate can also be sealed with vacuum grease and plain glass or plastic cover slides (22 mm diameter). The stackable, 24 well plates have distortion-free, flat bottom wells and a concave sitting drop post in the center of the well for concentric equilibration of the drop with the reagent. Each plate is individually sealed. The top of the plate and each of the 24 wells is a single, flat plane for smooth and easy seal application. Well spacing provides for a large seal area between wells to prevent cross contamination and evaporation.
上海金畔生物作为Hampton蛋白结晶产品的代理商,竭诚为您服务,欢迎新老客户咨询。
Cryschem Plate is large plate footprint with circular reagent reservoir. Cryschem plate approximate size: 15.1 cm x 10.6 cm x 2.2 cm. Approximate well size: 1.6 cm x 1.5 cm. Typical fill volume: 500 to 1,000 µl. Well capacity: 1.5 ml. Maximum drop volume on post: 40 µl. Recommended seal: HR3-511 Crystal Clear Sealing Tape (1.88 inch x 43.7 yard roll, with cutter) or HR4-511 Crystal Clear Sealing Tape (1.88 inch x 60 yard roll, without cutter).
Cryschem M Plate is microplate footprint with circular reagent reservoir. Cryschem M microplate approximate size: 128 mm x 86 mm x 14 mm. Approximate circular reservoir size: 15 mm wide x 9 mm deep. Typical reservoir volume: 500 µl. Well capacity: 1.1 ml. Maximum drop volume on post: 30 µl. Recommended seal: HR3-609 Crystal Clear Sealing Film (100 pack), HR4-521 ClearSeal Film (100 pack) or HR4-506 Crystal Clear Sealing Tape (3 inch x 55 yard roll, without cutter). HR4-508 Crystal Clear Sealing Tape (0.75 inch x 650 inch, with cutter) seals a single row at a time.
Cryschem S Plate is microplate footprint with square reagent reservoir. Cryschem S microplate approximate size: 128 mm x 86 mm x 14 mm. Approximate square reservoir size: 15 mm wide x 9 mm deep. Typical reservoir volume: 500 µl. Well capacity: 1.1 ml. Maximum drop volume on post: 30 µl. Recommended seal: HR3-609 Crystal Clear Sealing Film (100 pack), HR4-521 ClearSeal Film (100 pack) or HR4-506 Crystal Clear Sealing Tape (3 inch x 55 yard roll, without cutter). HR4-508 Crystal Clear Sealing Tape (0.75 inch x 650 inch, with cutter) seals a single row at a time.
Cryschem Plate
Cryschem plate

CAT NO NAME DESCRIPTION
HR3-158 Cryschem Plate 24 plate case
HR3-160 Cryschem Plate 100 plate case
HR1-002 Cryschem M Plate (round reagent reservoir) 50 plate case
HR3-308 Cryschem S Plate (square reagent reservoir) 50 plate case

Sigma代理  Abcam代理  CST代理  Santa Cruz代理  Biolegend代理 ebioscience代理  Invitrogen代理   millipore代理  BD流式抗体代理   GeneTe x抗体代理  Novus抗体代理   R&D代理 Biovison代理  Jackson代理  MBL抗体代理  ProSpec抗体代理  Bethyl抗体代理  Antibody Revolution抗体代理  Torrey Pines Biolabs代理  Amresco代理  MPbio代理  Laysan bio代理  NANOCS代理  Avanti代理  wako代理  lumiprobe代理(活性荧光染料)   NEB酶代理  Roche酶代理  Toyobo酶代理   USP代理  EP代理  Dr代理  TRC代理  TCI代理  Reagecon代理 Megazyme代理 Hampton代理(蛋白结晶) whatman代理(滤膜滤纸) GE代理(蛋白纯化) Corning康宁代理  Axygen代理 Falcon代理  NISSUI日水代理 Himedia代理 OXOID代理  BD培养基代理 Ludger代理(糖蛋白分析产品)  Eppendorf代理  Labnet代理  标准品代理 抗体代理 酶试剂代理  培养基代理 耗材代理 Elisa试剂盒代理 。

Hampton 蛋白结晶优化试剂 Optimization Screens

Hampton 蛋白结晶优化试剂 Optimization Screens

1、Solubility & Stability Screen  蛋白特异性试剂优化溶解性和稳定性
Protein specific agents for optimization of solubility & stability  
2、Solubility & Stability Screen 2   离子缓冲液
Buffer, pH & ionic strength screen for optimization of solubility & stability
3、Slice pH    PH缓冲液
pH & buffer screen for optimization of crystals or sample solubility & stability
4、Additive Screen  96孔板添加剂试剂盒
96 compound screen for optimization of crystal size & quality
5、Silver Bullets • Silver Bullets Bio
Small molecule additive screen for optimization of crystal size & quality
6、Detergent Screen
Detergent screen for optimization of crystals or sample solubility & stability
7、Ionic Liquid Screen
Ionic liquid additive screen for optimization of crystal size & quality
8、StockOptions Buffer Kits
Titrated buffer sets for optimization of crystals or sample solubility & stability
9、StockOptions Polymer
n of crystal size & quality
10、StockOptions Salt
Salt reagent kit for optimization of crystal size & qualit
11、Polymer reagent kit for optimizatioy
Proti-Ace
In situ proteolysis kit protein for crystallization screening & optimization
12、Reductive Alkylation
Reductive alkylation kit for crystallization screening & optimization
13、Silica Hydrogel Kit
pH neutral silica hydrogel matrix crystallization
14、Low Melting Agarose
Agarose gel matrix crystallization
15、CryoPro
Water soluble cryoprotectant reagent set
16、Heavy Atom Screens
Heavy atom kits for multiple isomorphous replacement
17、I3C Phasing Kit
Produce heavy atom derivative of biological macromolecules for phasing

Hampton PEGRx 聚乙二醇结晶试剂盒

Hampton PEGRx
PEGRx 1 • PEGRx 2 • PEGRx HT

Applications   主要是调节样本的PH值
  Primary and secondary, polymer and pH based crystallization screen for biological macromolecules
PEGRx is a primary and secondary, polymer and pH based crystallization screen developed at Hampton Research. It is designed to evaluate polymer based crystallization reagents and pH in low (PEGRx 1) to medium ionic strength (PEGRx 2). It is also designed for use as a secondary or optimization screen to follow the Hampton Research Index screen when polymer based reagents produce hits and interesting solubility leads.PEGRx 1 is a crystallization reagent kit designed to evaluate an array of polymers of varying molecular weight in a low ionic strength environment versus a wide range of pH. Polymer reagents include Polyethylene glycols, Polyethylene glycol monomethyl ethers, and Jeffamines®. The molecular weight range between 200 and 20,000 is evaluated in a low ionic strength formulation. Ten different buffers are used to span the range of pH between 3.5 and 9. The primary screen variables are polymer type, polymer molecular weight, pH and low ionic strength.
PEGRx 2 is a crystallization reagent kit designed to evaluate an array of polymers of varying molecular weight in a medium ionic strength environment in the presence of additives, salts, volatile organics and polyols versus a wide range of pH. Polymer reagents include Polyethylene glycols and Polyethylene glycol monomethyl ethers. The polymer molecular weight range between 200 and 20,000 is evaluated in a medium ionic strength formulation. Ten different buffers are used to span the range of pH between 3.5 and 9. The primary screen variables are polymer type, polymer molecular weight, pH and secondary reagents which include additives, salts, volatile organics and polyols.上海金畔生物作为Hampton蛋白结晶产品的代理商,竭诚为您服务,欢迎新老客户咨询。PEGRx 1 contains 48 unique reagents, 10 ml each.
PEGRx 2 contains 48 unique reagents, 10 ml each
PEGRx HT contains the 96 PEGRx 1 and PEGRx 2 reagent in a single Deep Well block format.
Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.
PEGRx 1 • PEGRx 2 • PEGRx HT
PEGRx
PEGRx 1 • PEGRx 2 • PEGRx HT
DesR crystals grown using Hampton Research PEGRx, Jin Ho Moon, Korea University.
CAT NO NAME DESCRIPTION
HR2-082 PEGRx 1 10 ml, tube format
HR2-084 PEGRx 2 10 ml, tube format
HR2-086 PEGRx HT 1 ml, Deep Well block format

Hampton Siliconized Glass Cover Slides

Hampton Siliconized Glass Cover Slides

ApplicationsHanging, sitting or sandwich drop crystallization
FeaturesHigh purity of glassSiliconized, hydrophobic glass surface0.22 mm & 0.96 mm glass thicknessThicker glass slides preserve temperature longer12 mm, 18 mm, & 22 mm glass diameterCircle & squareUV Compatible (>85% transmission)
12 x 0.22 mm Circle
18 x 0.22 mm Circle
22 x 0.22 mm Circle & Square
Description
Siliconized glass cover slides allow a droplet to be suspended in a position which provides near optimal conditions for vapor diffusion with the surrounding reservoir solution. These siliconized glass cover slides provide a consistent, high quality finish for crystallization experiments. The hydrophobic surface produces a drop which “stands well” and does not flatten on the glass. The siliconized surface prevents the adhesion of crystals and precipitate onto the glass surface. Use Dow Corning Vacuum Grease (HR3-510), Dow Corning 7 Release Compound (HR3-508), or immersion oil to seal cover slide to plate. Available in 12, 18 or 22 mm diameter circles and 22 mm diameter squares. Available in 0.22 mm or 0.96 mm glass thickness. The 0.96 mm thick slides are virtually unbreakable during crystallization handling.
The following slides are UV transmissable (>85%):
HR3-277 and HR3-279 – 12 mm x 0.22 mm Siliconized circle cover slides
HR3-231 and HR3-233 – 22 mm x 0.22 mm Siliconized circle cover slides
HR3-239 and HR3-241 – 18 mm x 0.22 mm Siliconized circle cover slides
HR3-215 and HR3-217 – 22 mm x 0.22 mm Siliconized square cover slides

图片

图片
Plain Glass Cover Slides
ApplicationsHanging, sitting or sandwich drop crystallization
Features
0.22 mm glass thickness
12 mm glass diameter
Hydrophilic glass surface
Circle & squareDescription
Plain, non-siliconized, hydrophilic glass cover slides. Useful for hanging drop, sitting drop, and sandwich drop vapor diffusion crystallization methods. The hydrophilic surface creates a drop which is more flat than a drop on a siliconized surface. This offers enhanced imaging for very small drops. Use Dow Corning® Vacuum Grease (HR3-510), Dow Corning® 7 Release Compound (HR3-508), or immersion oil to seal cover slide to plate.
HR3-209T 12 mm Plain circle cover slides for Tecan robot 5 oz case (~2,400 slides)
图片

图片
HR3-209T 12 mm Plain circle cover slides for Tecan robot 5 oz case (~2,400 slides)
PEN-VAC Kit
ApplicationsHolding and manipulating small, flat surfaces such as glass cover slides
FeaturesSelf-contained vacuumNo power neededCompactDescription
PEN-VAC is a great tool for handling small, flat surfaced objects such as plain and siliconized cover slides, as well as plastic slides. Simply depress the side button, touch the tip to the object to be lifted and release the button. PEN-VAC creates a totally self-contained vacuum that lifts up to 50 grams for up to one minute. Less than an ounce, the lightweight aluminum body fits in a pocket. No power supply needed. The kit includes one PEN-VAC with 5 3/4″ blue body, (3) angled and (3) straight probes with (2) each 1/8”, 1/4”, 3/8” diameter blue silicone vacuum cups . It is packaged in a clear plastic storage case.
图片
HR3-251  PEN-VAC Kit

Hampton 水晶透明密封带Crystal Clear Sealing Tape

Hampton 水晶透明密封带Crystal Clear Sealing Tape
Crystal Clear Sealing Tape
3 inch, 1.88 inch, 1.88 inch with dispenser, 0.75 inch with dispenser (left to right)
Crystal Clear Sealing Tape
0.75 inch Crystal Clear Sealing Tape
Applications  应用
Sealing tape used to seal sitting drop crystallization experiments
Description
These optically clear tapes are compatible with protein crystallization reagents. The polypropylene Crystal Clear Sealing Tapes use acrylic solvent based adhesives which are compatible with aqueous crystallization reagents.
Catalog number HR3-511 is a 1.88 inch (48 mm) wide, 3 mil tape on a 43.7 yard (40 M) roll with a 1.5 inch core and is supplied with a green dispenser / cutter.Catalog number HR4-511 is a 1.88 inch wide, 3 mil tape on a 60 yard roll with a 3 inch core and no dispenser / cutter.Two strips of the HR3-511 or HR4-511 will seal a Corning, Cryschem, CrystalClear Strip, Greiner, Intelliplate, Linbro, Swissci (MRC), VDX and VDXm plate.Catalog number HR4-506 is a 3 inch wide, 3 mil tape on a 54.86 yard roll with a 3 inch core and no dispenser / cutter.One strip of the HR4-506 will seal a Corning, Cryschem M, CrystalClear Strip, Greiner, Intelliplate, Swissci (MRC) and VDXm plate.Crystal Clear Mini Sealing Tape HR4-508 is a 0.75 inch (19 mm) wide, 3 mil tape on a 650 inch (16.5 M) roll and is supplied with a clear dispenser / cutter. The tape is useful for resealing or patching wells after mounting crystals. The tape is also wide enough to seal a single row of a Cryschem S or Cryschem M plate.See chart for tape and plate compatibility.

Hampton 48孔坐滴蛋白结晶板 48-Well Crystallization Plate

Hampton 48孔坐滴蛋白结晶板 48-Well Crystallization Plate
Applications

Sitting drop crystallization
Features

One drop per reservoir
SBS format
48 well plate
9 mm standard distance between wells
Drop volume: Up to 10 µl
Reservoir volume: 50 to 200 µl
Micro-numbering alongside drop volumes
Rigid plate structure
Wide partition walls between wells improve sealing
Developed in conjunction with the MRC Laboratory of Molecular Biology in Cambridge, United Kingdom
UV compatible (UVP)
Description
MRC Maxi 48-Well Crystallization Plate for Automated Optimization
The MRC Maxi optimization plate is a breakthrough for macromolecular crystallization presented in a 48 well format. Offering easy to automate crystallization optimization with large sitting-drops, the new MRC Maxi Crystallization plate is the perfect solution. Manufactured by Swissci AG, the plate offers an SBS format while providing 48 wells. MRC Maxi is intended for large drops and is compatible both with standard robotic systems as well as manual pipetting.
The plate was developed at the MRC Laboratory of Molecular Biology (Cambridge, UK) in collaboration with Jan Löwe and Fabrice Gorrec. It is a result of many years of experience in successful robotic high-throughput crystallization and complements the original MRC crystallization plate, which is intended for smaller drop volumes and higher throughput during screening.
Drop volumes of up to 10 µl are possible. The 9 mm standard distance between wells is preserved, enabling the use of multi-channel manual pipettes and robotic liquid handlers, making MRC Maxi one of the most automation-friendly optimization plates on the market.
MRC Maxi is covered by global intellectual property and design registration as are the Swissci AG MRC 2 lens 96 well plates. Several breakthrough features of the original MRC plate have been maintained. Wells are labeled individually. Drops are raised for easy access during crystal retrieval. MRC Maxi uses the same proprietary polymer specially selected for the purpose of UV light visualization and the material used keeps through-plastic evaporation to a minimum. Well shapes are spherical but shallow.
The MRC Maxi Crystallization plate offers unique properties that make it the ideal choice for microliter-sized optimization experiments and is made from UV compatible UVP.
The advantages of the MRC Maxi Crystallization plate – in brief
Easy Crystal Retrieval
Raised wide wells make the crystal mounting especially easy.
Easy Viewing
The wells are wide conical.
Each well has a micro lens for perfect illumination.
Micro numbering readable under the microscope for each well.
The optically superior polymer (UVP) is UV transmissible.
Better Sealing
Wide partition walls between the wells give plenty of area for good sealing with tape.
Very Rigid, Automation-Friendly Plate Design
The UVP polymer reduces through-plastic evaporation to a minimum.
SBS Standard
The plates are designed to the SBS standard and are compatible with all common holders.
9 mm distance from well-to-well within columns, 18 mm distance within rows.
Unique Polymer (UVP)
Ultra-low sample binding.
No static charging.
Recommended Volumes
Volumes validated for MRC Maxi are up to 10 µl of sample drop and 200 µl of the crystallization reagent.
CAT NO NAME DESCRIPTION
HR3-179 MRC Maxi 48-Well Crystallization Plate 10 plate case
HR3-180 MRC Maxi 48-Well Crystallization Plate 40 plate case

Hampton 蛋白结晶试剂–Crystal Screen

Hampton 蛋白结晶试剂–Crystal Screen
Crystal Screen • Crystal Screen 2 • Crystal Screen HT

Applications
 Primary screen for proteins, soluble peptides, nucleic acids, & water soluble small molecules
 Sparse matrix additive screen
Features
 The original sparse matrix screen
 Sparse matrix formula efficiently samples salts, polymers, organics, & pH
 Proven effective with more than 1,000 biological macromolecules
 Tube or Deep Well block format

Description
The Crystal Screen and Crystal Screen 2 reagent kits are designed to provide a highly effective and rapid screening method for the crystallization of macromolecules. The screens are simple and practical for finding initial crystallization conditions. The initial crystallization conditions for more than 1,000 proteins, peptides, oligonucleotides, and small molecules have been determined using Crystal Screen.
A highly effective approach to overcome the exhaustive search for suitable crystallization conditions is the use of a sparse matrix method of trial conditions that is biased and selected from known crystallization conditions for macromolecules. The formulation utilized in Crystal Screen and Crystal Screen 2 evaluates 96 unique mixtures of pH, salts, polymers and organics, and their ability to promote crystal growth.
Crystal Screen contains 50 unique reagents, 10 ml each and is based on the sparse matrix formulation first described by Jancarik and Kim in 1991.
Crystal Screen 2, an extension of Crystal Screen, contains 48 unique reagents, 10 ml each and is based on the formulation first described by Cudney et al in 1994.
Crystal Screen HT contains 1 ml each of reagents 1-48 from Crystal Screen and all 48 reagents from Crystal Screen 2 in a single Deep Well block format.
Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.
Crystal Screen • Crystal Screen 2 • Crystal Screen HT
Crystal Screen • Crystal Screen 2 • Crystal Screen HT
Crystals of a carbohydrate processing enzyme grown using Hampton Research Crystal Screen. Shirley Roberts, York Structural Biology Laboratory, York, United Kingdom.
Crystal Screen • Crystal Screen 2 • Crystal Screen HT
Crystal of zRFP574 red fluorescent protein grown using Hampton Research Crystal Screen 2. Pletneva et al. Acta Cryst. D62, 527-532 (2006). Nadya, Russian Academy of Science, Moscow, Russia.

CAT NO NAME DESCRIPTION
HR2-110 Crystal Screen 10 ml, tube format
HR2-112 Crystal Screen 2 10 ml, tube format
HR2-130 Crystal Screen HT 1 ml, Deep Well block format

Hampton蛋白结晶工具及仪器

Hampton蛋白结晶工具及仪器
CryoTong™ – Long
ApplicationsCrystal transfer under cryo temperature
FeaturesArtery clamp style closure30 seconds of cryo temperature180 mm length
Description
The CryoTong is a tool used to manually transfer a crystal mounted on a CrystalCap™ from liquid nitrogen to a magnetic base in a goniometer head positioned in a cryogenic stream, and then back to liquid nitrogen. The one-piece, compact CryoTong is available in two lengths. The long CryoTong is approximately 180 mm in overall length. The artery clamp style maintains the CryoTong in the closed position until the clamp is squeezed, which opens the opposing heads. The heads are non-magnetic stainless steel. The handle is magnetic stainless steel. The inside of the head is machined to closely surround the CrystalCap with loop and crystal in place. A small retaining lip is machined into the lower portion of the head to prevent the CrystalCap from slipping out of the CryoTong when the tool is in the closed position. The CryoTong can maintain the temperature of the crystal at -160°C for up to 30 seconds during room temperature crystal transfers. Choose the proper CryoTong size based upon the pin length required by the configuration of the x-ray data collection hardware used. The 18 mm CryoTong (HR5-112) is to be used with the CrystalCap HT and any other CrystalCap configured for 18 mm.HR5-114 Long CryoTong 18 mm, 180° features the head in alignment with the handle of the CryoTong.

图片

图片

图片

图片

图片

图片
Vial Clamp™ – Straight
ApplicationsVial support and manipulation
FeaturesStraight end tipHemostat style closureDescription
The Vial Clamp™ – Straight is a chrome plated, hemostat style tool. It has a tip shaped to hold the storage vial of all the CrystalCap Systems™ straight when the clamp is closed. The clamp can be locked using the hemostat style closure. This clamp makes it easy to dip the storage vial into liquid nitrogen for crystal storage. The complete length of the clamp is straight, with an overall length of 195 mm. When the vial is placed in the clamp, the length of it is positioned perpendicular, 90° to the length of the clamp.
图片
CrystalWand™ Magnetic
ApplicationsCrystalCap Magnetic & CrystalCap Copper Magnetic handling toolDescription
The CrystalWand Magnetic is designed to be used exclusively with the CrystalCap Magnetic, CrystalCap Copper Magnetic, and CrystalCap HT systems during transfer of the caps from the vial to the goniometer head and from the goniometer to the vial. The 6 1/2” (165 mm) long chrome plated steel wand features a plastic housing enclosing a spring tensioned plunger that when depressed, moves a non-magnetic steel platform away from the magnet housed in the end of the wand. This causes the steel CrystalCap to detach from the wand and be placed readily into the vial or the CryoTong™. When the platform is retracted, the wand securely holds the steel CrystalCap Magnetic. The CrystalWand Magnetic 45° (McMiken Tool) offers the same functionality but is bent at a 45° angle at approximately 2.5 cm from the magnet end.HR4-729 CrystalWand Magnetic, StraightHR4-315 CrystalWand Magnetic, 45° (McMiken Tool)
图片

图片

图片
Vial Clamp™ – Curved
ApplicationsVial support & manipulation
FeaturesCurved end tipHemostat style closureDescription
The Vial Clamp – Curved is a chrome plated, hemostat style tool. It has a tip shaped to hold the storage vial of all the CrystalCap Systems at an angle when the clamp is closed. The clamp can be locked using the hemostat style closure. The end of the clamp, where the vial is held, is curved at either a 45°/135° or 110°/ 70° angle. When the vial is placed in the clamp, the length of it is positioned to the clamp at either of those same angles. The overall length of each clamp is the same, 195 mm.HR4-671 Vial Clamp – Curved 45°/135°HR4-672 Vial Clamp – Curved 110°/70°
图片

CrystalCap™ Holder
pplicationsCrystalCap support inside stainless steel dewars
FeaturesAdjustable heightSupports up to 8 CrystalCaps15 ml vial position for liquid propane500 and 1,000 ml versionsDescription
CrystalCap Holders are convenient stands for holding all CrystalCap™ systems in liquid nitrogen dewars during crystal cryogenic procedures. Available in two sizes. Both holders feature spring-clips to secure the CrystalCap Vials in the holder. Both stands have 3 inches of adjustable Z (height) which allows one to raise or lower the CrystalCaps to the appropriate height, depending upon the liquid nitrogen level in the dewar. Each holder is supplied with a socket driver for height adjustment.500 ml version holds five CrystalCaps, two 15 ml vials (for liquid propane procedures) and fits into the 500 ml dewar. 1,000 ml version holds eight CrystalCaps, two 15 ml vials (for liquid propane procedures) and fits into the 1,000 ml dewar.HR4-707 CrystalCap Holder – 500 ml
HR4-706  Replacement Height Adjustment Tool
图片

图片

Hampton蛋白结晶小瓶和结晶柱底座CrystalCap™

Hampton蛋白结晶小瓶和结晶柱底座CrystalCap™

Applications

Cryocrystallography  低温结晶学
Features

SSRL style sample mount for cryocrystallography
CrystalCap attaches magnetically to CrystalCap Vial and Magnetic Goniometer Base
Conical shape with ledge compatible with SSRL style grippers, auto mounters and sample handlers

Description
The CrystalCap is a magnetic sample mount (also known as a cap, pin or goniometer base) designed for cryocrystallography systems that accept SSRL style sample mounts. The CrystalCap attaches to a magnetic CrystalCap Vial and Magnetic Goniometer Base. The tip of the CrystalCap accepts a Mounted CryoLoop™ or MicroTube™ fitted with a CryoLoop™.
The CrystalCap Vial is a 1.8 ml cryo vial featuring two small vents. A ring magnet is molded into the open end of the vial so that when the cap is positioned in the vial, the ring magnet holds the cap on the vial during cryogenic storage.The HR4-904 CrystalCap Vial does not have a magnet on the bottom of the vial.
The conical shape with ledge is compatible with SSRL style grippers, auto mounters and sample handlers.
Compatible with the following Synchrotron Radiation Beamlines
North & South America
• The Advanced Light Source, Berkeley, California ALS 4.2.2, ALS 11.3.1, ALS 12.2.2, ALS 12.3.2
• The Advanced Photon Source, Argonne, Illinois APS 14-BM-C BioCARS, APS 14-ID-B BioCARS
• Cornell High Energy, Synchrotron Source, Ithaca, New York CHESS A1, CHESS F1
• Canadian Light Source, Saskatchewan, Canada, CLS 08ID-1, CLS 08B1-1
• National Synchrotron Light Source, Upton, New York NSLS X4C
• Stanford Synchrotron Radiation Laboratory, Menlo Park, California SSRL BL7-1, SSRL BL9-1, SSRL BL9-2, SSRL BL11-1, SSRL BL12-2, SSRL BL14-1
Asia & Australia
• Shanghai Synchrotron Radiation Facility, Shanghai, China SSRF BL17U1
• National Synchrotron Radiation Research Center, Taiwan NSRRC BL13B1, NSRRC BL13C1
• Pohang Accelerator Laboratory, Pohang, South Korea PAL 2D, PAL 5C, PAL 7A
• Photon Factory, Tsukuba, Japan PF BL-5A, PF BL-17A, PF AR-NW12A
• Super Photon ring-8 GeV, Japan SPRING-8 BL12B2, SPRING-8 BL24XU, SPRING-8 BL26B1, SPRING-8 BL26B2, SPRING-8 BL32B2, SPRING-8 BL32XU, SPRING-8 BL38B1, SPRING-8 BL41XU, SPRING-8 BL44B2, SPRING-8 BL44XU
CrystalCap™
CrystalCap
CrystalCap™
CrystalCap & Vial
CrystalCap™
CrystalCap
Hampton蛋白结晶小瓶和结晶柱底座 CrystalCap™

CAT NO NAME DESCRIPTION
HR4-733 CrystalCap with Vial – 60 pack
HR4-902 CrystalCap without Vial – 60 pack
HR4-904 CrystalCap Vial Vial only – 30 pack

Hampton GRAS 5 • GRAS 6 Screens

Hampton GRAS 5 • GRAS 6 Screens
Applications
 GRAS reagent crystallization screen for proteins, including monoclonal antibodies, where Polyethylene glycol is the primary reagent, sampling pH 4.5 to 10
. Identify GRAS based reagents that promote crystallization of biotherapeutics for bioprocess, bioformulation, and continuous flow manufacturing applications
Features

Developed at Hampton Research
Generally Recognized As Safe reagent formulation
Samples pH 4.5 to 10; 8 unique buffers
Primary crystallization reagent:

GRAS 5: PEG 300, 400, MME 550, & 600
GRAS 6: PEG 1,000, MME 2,000, 3,350 & 4,000

 

Vapor diffusion, microbatch, free interface diffusion
Reagents soluble between 4°C and 30°C

Description

GRAS Screen™ 5 and 6 were developed by Hampton Research for the crystallization of proteins, including monoclonal antibodies. Each of the chemicals in GRAS Screen 5 and 6 has been used under one or more of the following categories. As (1) a Generally Recognized As Safe (GRAS) substance, (2) a pharmaceutical excipient, (3) a normal physiological constituent, (4) a metabolic byproduct, and/or (5) a Everything Added to Food in the United States (EAFUS) substance.
GRAS Screen 5 samples four low molecular weight Polyethylene glycols (300, 400, MME 550, and 600) at three concentrations versus eight unique buffers encompassing pH 4.5 to 10. GRAS Screen 5 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 5 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.
GRAS Screen 6 samples four medium molecular weight Polyethylene glycols (1,000, MME 2,000, 3,350, & 4,000) at three concentrations versus eight unique buffers encompassing pH 4.5 to 10. GRAS Screen 6 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 6 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.